Flue Gas Analyser testo 330-2 LL – Chimney Sweep Set
Flue gas analysers from testo are standard tools for adjusting, servicing and testing oil-fired, gas-fired and condensing heating systems. They measure O₂, CO, flue gas temperature and draught, calculate efficiency and losses, and document the results directly on site.
Key Benefits at a Glance
- 330-2 LL flue gas analyser with fresh air valve to protect the CO measuring cell and extend the CO measuring range to 30.000 ppm
- 4-year warranty on user-replaceable sensors, including sensor monitoring, with a service life of up to 6 years
- Single-hose connection: one simple action securely connects all channels for flue gas measurement (gas paths, draught and temperature sensor integrated into the flue gas probe)
- TÜV-tested according to 1. BImSchV EN 50379, Parts 1-3
Scope of delivery
Measuring instrument testo 330-2 LL with H2-compensated CO measuring cell, a modular 300 mm flue gas probe, a 190 mm combustion air temperature probe and a mains adapter.Technical specifications
| General technical specifications | |
|---|---|
| Weight | 600 g (without rechargeable battery) |
| Dimensions | 270 x 90 x 65 mm |
| Operating temperature | -5 to +45 °C |
| Display size | 240 x 320 pixels |
| Display functions | Colour graphic display |
| Power supply | Rechargeable battery pack 3.7 V / 2.6 Ah; mains adapter 6 V / 1.2 A |
| Maximum memory capacity | 500.000 measured values |
| Storage temperature | -20 to +50 °C |
| Differential pressure – piezoresistive | |
| Measuring range | 0 to 300 hPa |
| Accuracy | ±1 % of measured value (50,1 to 100,0 hPa), ±1,5 % of measured value (remaining measuring range), ±0,5 hPa (0,0 to 50,0 hPa) |
| Resolution | 0,1 hPa |
| O₂ in flue gas | |
| Measuring range | 0 to 21 Vol. % |
| Accuracy | ±0,2 vol. % |
| Resolution | 0,1 Vol. % |
| Response time t₉₀ | < 20 s |
| CO in flue gas (with H₂ compensation) | |
| Measuring range | 0 to 8000 ppm |
| Accuracy | ±10 ppm or ±10 % of measured value (0 to 200 ppm), ±10 % of measured value (2001 to 8000 ppm), ±20 ppm or ±5 % of measured value (201 to 2000 ppm) |
| Resolution | 1 ppm |
| Response time t₉₀ | < 60 s |
| COlow in flue gas (with H₂ compensation) | |
| Measuring range | 0 to 500 ppm |
| Accuracy | ±5 % of measured value (40 to 500 ppm), ±2 ppm (0 to 39,9 ppm) |
| Resolution | 0,1 ppm |
| Response time t₉₀ | < 40 s |
| CO measurement (with H₂ compensation), automatic dilution | |
| Measuring range | 0 to 30000 ppm |
| Accuracy | ±100 ppm (0 to 1000 ppm), ±10 % of measured value (1001 to 30000 ppm) |
| Resolution | 1 ppm |
| NO in flue gas | |
| Measuring range | 0 to 3000 ppm |
| Accuracy | ±5 % of measured value (101 to 2000 ppm), ±10 % of measured value (2001 to 3000 ppm), ±5 ppm (0 to 100 ppm) |
| Resolution | 1 ppm |
| Response time t₉₀ | < 30 s |
| NOlow in flue gas | |
| Measuring range | 0 to 300 ppm |
| Accuracy | ±5 % of measured value (40 to 300 ppm), ±2 ppm (0 to 39,9 ppm) |
| Resolution | 0,1 ppm |
| Response time t₉₀ | < 30 s |
| Differential pressure draught measurement in flue gas – piezoresistive | |
| Measuring range | -9,99 to +40 hPa |
| Accuracy | ±0,02 hPa or ±5 % of measured value (-0,50 to +0,60 hPa), ±0,03 hPa (+0,61 to +3,00 hPa), ±1,5 % of measured value (+3,01 to +40,00 hPa) |
| Resolution | 0,01 hPa |
| Temperature | |
| Measuring range | -40 to +1200 °C * |
| Accuracy | ±0,5 % of measured value (remaining measuring range), ±0,5 °C (0 to +100,0 °C) |
| Resolution | 0,1 °C (-40 to +999,9 °C), 1 °C (> +1000 °C) |
| footnote_ | * Measuring range depends on the flue gas probe used |
| Efficiency determination, Eta (calculated) | |
| Measuring range | 0 to 120 % |
| Resolution | 0,1 % |
| Flue gas heat loss (calculated) | |
| Measuring range | 0 to 99,9 % |
| Resolution | 0,1 % |
| CO₂ determination (calculated from O2) | |
| Measuring range | 0 to CO₂ max (display range) |
Operating conditions
Portable handheld measuring instrument for use in boiler rooms and buildings; rechargeable battery operation with mains adapter.
- Operating temperature: -5 to +45 °C
- Storage temperature: -20 to +50 °C
- For construction sites
- For temporary use
- For hard-to-reach areas
- Not suitable for potentially explosive atmospheres (no ATEX certification)
Typical applications
Skilled trades · Building management & facilities · Energy supply · Engineering & technical services
Product information
- Manufacturer: Testo SE & Co. KGaA, Celsiusstraße 2, 79822 Titisee-Neustadt, Germany
- Manufacturer's part number: 0563 3372 76
Downloads
We offer additional discounts for larger order quantities. Let us know the quantity required and we will prepare a tailored quotation.
Request a bulk quotation
Technical Details
| Operating Conditions: | For construction sites, For hard-to-reach areas, For temporary use |
|---|---|
| Primary Function: | Measuring & Testing |
| Sectors/Industry: | Building & Facility Management, Energy Supply & Wind Power, Maintenance & Technical Services, Trades & Workshops |
Login
Stock & Custom Solutions
Standard range from stock plus made-to-order solutions to your specifications.
Personal Expert Consultation
Direct contact with our experts – we find the technical solution for your problem.
Brand Quality
Products from renowned manufacturers – certificates and declarations of conformity per product on request.
Delivery DE & Nordics
Reliable delivery to Germany, Denmark, Norway, Sweden and Finland – Austria and Switzerland on request.
Our Bestsellers
The best-selling products for professional users.
About Hansehandel
What we at HANSEHANDEL, our products and solutions stand for
Our
Mission
Our mission is to make industrial procurement for our partners in Germany and Northern Europe as efficient and reliable as possible. We deliver not just products, but engineering expertise and dependable, personal support.
Our
Vision
We aim to be the agile partner for MRO solutions for companies in Scandinavia and Germany – with technical know-how, deep market understanding and a clear focus on industrial safety.
Frequently Asked Questions
Contact Us
We look forward to your technical challenge.